dB Development
Aerial view of Greenwich, Connecticut, showcasing waterfront homes along Long Island Sound, lush green neighborhoods, and the distant New York City skyline.

Greenwich, CTZoning for Custom Homes

Property tool

What zone is my property?

Enter an address in Greenwich, CT and we'll look up the zoning district for you.

What Is a Zone, and Why Does It Come First?

Every property in Greenwich sits in a zoning district, and that district sets the rules for what can legally be built there, before any design work starts. The zone determines the maximum size, height, and setbacks of a house, and how much of the lot can be covered by the house, driveway, and pool combined.

That’s why zoning comes first. A design that doesn’t fit the zone’s limits isn’t buildable as is. It needs a variance, a redesign, or a different lot. Knowing the zone before you start design work means the design work is actually usable.

Greenwich has six single family zones: RA-4, RA-2, RA-1, R-20, R-12, and R-7, named for lot size in acres or square feet. Two things set Greenwich apart from neighboring towns: an explicit Floor Area Ratio (FAR) for every zone, and a Green Area requirement that goes well beyond a simple coverage cap. Find your zone above, then check the tables for what it allows.

RA-4
4 acres
RA-2
2 acres
RA-1
1 acre
R-20
20,000 sf
R-12
12,000 sf
R-7
7,500 sf
RA-4
125 ft
RA-2
125 ft
RA-1
125 ft
R-20
100 ft
R-12
80 ft
R-7
65 ft
RA-4
Circle, 300 ft dia.
RA-2
Circle, 200 ft dia.
RA-1
Circle, 150 ft dia.
R-20
Circle, 100 ft dia.
R-12
Rect. 60×100 ft
R-7
Rect. 45×85 ft
RA-4
RA-2
RA-1
R-20
R-12
R-7
RA-4
50 ft
RA-2
47½ ft
RA-1
40 ft
R-20
37½ ft
R-12
35 ft
R-7
35 ft
RA-4
.0625
RA-2
.09
RA-1
.135
R-20
.225
R-12
.315
R-7
.36
RA-4
84%
RA-2
78%
RA-1
72%
R-20
62%
R-12
55%
R-7
50%
RA-4
75 ft
RA-2
75 ft
RA-1
50 ft
R-20
40 ft
R-12
35 ft
R-7
25 ft
Side, Rear & Corner-Lot Setbacks

Side yards in the four smaller zones aren't a single number — Greenwich sets a minimum for one side plus a combined minimum for both sides added together, so one generous side can't be offset by an undersized one beyond a point.

Min. side yard (one)
RA-4
50 ft
RA-2
35 ft
RA-1
25 ft
R-20
15 ft
R-12
10 ft
R-7
5 ft
Min. side yards (both, combined)
RA-4
RA-2
RA-1
R-20
35 ft
R-12
25 ft
R-7
15 ft
Min. rear yard
RA-4
75 ft
RA-2
75 ft
RA-1
50 ft
R-20
40 ft
R-12
35 ft
R-7
25 ft
Min. street-side yard (corner lot)
RA-4
62½ ft
RA-2
55 ft
RA-1
37½ ft
R-20
27½ ft
R-12
22½ ft
R-7
15 ft
  • RA-4 and RA-2 don't set a combined-both-sides minimum — the single-side figure applies independently to each side.
  • On a corner lot, the street-side yard is a separate, generally shorter figure than the standard side yard — but every corner lot's yards remain subject to the visibility-at-intersections rule near the street corner itself.
Visualizing the Setbacks

Numbers in a table are easy to skim past. Here's what they actually mean on the ground — select a Greenwich zone to see its setbacks drawn to scale. The shaded band is where nothing can be built; the white area is your buildable envelope.

PROPERTY LINEHOUSESTREET LINEREARFRONTSIDESIDE35 ft front35 ft rear10 ft side10 ft side
Property lineSetback area — no structures permittedBuildable envelope

Illustrative, drawn to scale for R-12. Lot dimensions are normalized; the envelope shape changes with the zone's setbacks.

Accessory Structures in Rear Yards

Greenwich allows accessory buildings to sit closer to the side and rear lines than the house — but with a real ceiling on how large an accessory structure can be before it needs a special exception from the Planning & Zoning Board of Appeals (PZBA).

Min. side yard
RA-4
35 ft
RA-2
25 ft
RA-1
15 ft
R-20
10 ft
R-12
5 ft
R-7
5 ft
Min. rear yard
RA-4
35 ft
RA-2
25 ft
RA-1
15 ft
R-20
10 ft
R-12
5 ft
R-7
5 ft
Max. size w/o PZBA exception
RA-4
1,200 sf
RA-2
1,200 sf
RA-1
800 sf
R-20
800 sf
R-12
600 sf
R-7
600 sf
General accessory building rulesAccessory buildings are capped at 25 ft in height and must sit at least 5 ft from any other structure on the lot. None of this reduced setback applies to accessory buildings serving a multi-family development of more than 8 families, or to structures otherwise regulated elsewhere in the code. On a corner lot, an accessory building can't sit closer to the street-side line than half the combined side-and-front yard required of the lot behind it.
Setback Exceptions

Two categories get their own precise rules rather than falling under the general setbacks above: architectural projections, and decks or patios near the ground.

  • Bay windows, entrances, vestibules, chimneys, balconies, and similar projections up to 10 ft wide — plus cornices, eaves, and comparable features — may extend up to 2 ft into a required yard. Nothing except an eave or a minor feature under 6 in (sill, leader, gutter, belt course) may come within 5 ft of a property line.
  • A projection that connects to the ground counts toward lot coverage and can't sit within the Green Area.
Decks & patios — how close they can sit, by zone
R-6, R-7, R-12
5 ft
R-20, RA-1
10 ft
RA-2, RA-4
25 ft
  • This closer distance only applies to an uncovered deck or patio built no more than 3 ft above existing grade. Built higher than 3 ft above grade, a deck or patio is treated as part of the principal structure and needs the full zone setback instead.
  • A deck or patio in the front yard isn't allowed in the required front or side setback at all — the reduced distances above apply to side and rear yards only.
  • Uncovered stairs may be built in a required front or rear yard freely, but in a side yard must stay at least 5 ft from the property line.
Coastal Site Plan Review

Like Greenwich's other shoreline neighbors, properties near Long Island Sound — Belle Haven, Byram, Old Greenwich, Riverside, and similar areas — layer an additional review on top of standard zoning rather than following a separate dimensional zone.

The short versionWork within the coastal boundary generally requires Coastal Site Plan review under the Connecticut Coastal Management Act — but routine residential work is broadly exempted from full Commission review (subject to administrative sign-off) when it's minor: normal walks, decks, patios, driveways, pools, tennis courts, docks, and detached accessory structures; a single-family home itself, unless on an unconnected island or within 100 ft of tidal wetlands, coastal bluffs, or beaches and dunes. Anything closer to those specific resource areas, or larger in scope, needs the full coastal review process.
Nonconforming Buildings & Yards

Greenwich's rules for additions to a nonconforming house are unusually specific — real numeric limits rather than a general "don't make it worse" principle alone.

What "nonconforming" actually meansA lawfully existing building, lot, or use may continue even where it doesn't meet current standards, provided the nonconformity is actual and hasn't been abandoned. A nonconforming lot can't be altered in a way that increases the degree of nonconformity.
  • One horizontal addition is allowed into the same nonconforming yard. The addition can't further encroach into the required yard, and its width can't exceed half the width of the nonconforming portion it's attached to — this option can only be used once.
  • One vertical addition is allowed, within limits. A single vertical addition, alteration, or reconstruction may raise the height of a nonconforming portion of the building, provided it doesn't push the height above 75% of the zone's maximum, doesn't add more than 15% to that floor's area, and keeps at least 10 ft of separation from the nearest adjoining building.
  • "Substantial improvement" triggers full conformance. For a building under 50 years old (or not eligible for the National Register of Historic Places), a substantial improvement requires the whole structure to meet current yard, height, story, and FAR standards — though a compliant addition itself doesn't count toward triggering that threshold.
  • Rebuilding after casualty damage means matching what was lost — not a percentage test. If a nonconforming building is damaged by fire, explosion, or similar casualty, it may be restored only if the rebuilt structure covers no more area, has no greater cubic content or floor area, and is substantially identical in appearance to what existed before. There's no 50%-of-value threshold here as in some neighboring towns; rights to rebuild must be exercised by filing plans within one year of the damage.
This reference summarizes select provisions of the Greenwich Municipal Code (Sec. 6-205 and related sections) for general planning purposes and does not cover every zone, overlay district, or exception — including R-6 and R-MF, which permit two-family and multi-family housing under a different set of standards, and the Village District equivalents that apply in Greenwich's business zones. Zoning is parcel- and district-specific, subject to change, and interacts with coastal, wetlands, and flood regulations that can further restrict a given lot. Whether a specific lot or structure qualifies as nonconforming — and what that allows — depends on its exact history and current condition. Always confirm current requirements for your specific property with the Greenwich Planning & Zoning Department before finalizing a design. dB Development is happy to help evaluate a specific lot as part of an initial consultation.
Source: Greenwich Municipal Code, Sec. 6-205 Schedule of Required Open Spaces, Limiting Heights and Bulk of Buildings, as amended. Reference only — verify current requirements with the Greenwich Planning & Zoning Department before design.

Building in a nearby town?

Zoning changes at the town line. These neighboring towns have their own districts, setbacks, and coverage limits.

All Fairfield County zoning guides